HR61 Small Linear Actuator | OEM Configuration

HR61 Small Linear Actuator | OEM Configuration

HR61 is a compact OEM linear actuator platform for space-constrained motion systems. Confirm voltage, rated load, stroke, speed, duty cycle, mounting dimensions, feedback, material, enclosure rating and compliance documentation against the approved drawing, quotation and test data before production.

Configuration pointWhat to confirm
ElectricalSelected voltage, current requirement, cable and controller interface
MechanicalStroke, retracted/extended length, mounting ends and installation geometry
PerformanceRated load, speed and duty cycle for the selected configuration
FeedbackLimit switch, Hall or other feedback only when specified and documented
EnvironmentIngress protection, temperature and exposure requirements backed by matching test data
ComplianceApplicable declaration, certificate or report for the ordered configuration

Contact us to get a quote and information on this product:

Usually we will contact you within 30 minutes
Share your love

HR61 compact linear actuator for OEM motion systems

The HR61 is a small linear actuator platform for OEM products where installation space is limited. Selection should start from the actual load, travel, mounting envelope, electrical interface and operating environment rather than from a fixed catalog specification.

For compact-motion projects, buyers can review ActuLift’s Micro & Mini Linear Actuators, 12V Linear Actuators, 24V Linear Actuators, Brackets & Mountings and Control Boxes & Controllers while preparing the complete motion package.

Configuration points to confirm

ItemVerification requirement
Product identityHR61 small linear actuator / compact OEM motion component
VoltageConfirm the selected DC voltage, current demand and controller compatibility
LoadConfirm the rated working load at the required speed and mounting condition
Stroke and dimensionsConfirm stroke, retracted length, extended length and installation dimensions on the approved drawing
Speed and duty cycleConfirm travel speed under load and allowable duty cycle for the selected configuration
Feedback/controlConfirm limit-switch, Hall or other feedback only when included in the quoted HR61 version
Material and finishConfirm housing/rod materials and finish on the approved BOM, drawing or quotation
EnvironmentRequest the applicable enclosure/environmental test report before specifying an IP rating, temperature range or outdoor suitability
ComplianceRequest the current declaration, certificate or report applicable to the ordered configuration and destination market

Keep HR61 and HR61H specifications separate

HR61 and HR61H are separate model designations. Do not transfer speed, load, noise or feedback values from HR61H to HR61 unless the approved project documentation explicitly identifies the same value for the selected HR61 configuration.

If a higher-speed version is required, compare the model requirement separately and request the drawing, performance data and quotation for that exact model.

Load, stroke and speed must be evaluated together

For a compact actuator, load capability, travel speed, stroke, mounting geometry and duty cycle are interdependent. A maximum number from a catalog should not be treated as a universal capability across every configuration.

For quotation, provide the real load direction, required travel, desired movement time, installation angle and expected cycle pattern. Ask for the performance point that matches those conditions and, where it matters, the supporting test data.

Feedback and control are configuration-specific

Do not assume that Hall feedback, integrated limit switches or a particular control method is included in every HR61 order. If the application needs position feedback, end-of-travel switching or controller-based monitoring, define it in the inquiry and request documentation for the exact quoted version.

Environmental and compliance boundaries

The current HR61 evidence set does not include an independent ingress-protection report, acoustic report, temperature test, material certificate or CE/RoHS documentation. Previously published IP, noise, temperature, material or compliance statements therefore should not be used as verified specifications without matching evidence.

If the application involves moisture, cleaning, dust or outdoor exposure, define the real environment and request the applicable enclosure test evidence. For sealed actuator selection, compare the requirement with ActuLift’s Waterproof Linear Actuators category.

What OEM buyers should send for quotation

  • Required DC supply and controller interface
  • Working load and load direction
  • Target stroke and installation envelope
  • Target travel time or speed under load
  • Duty cycle and expected operating frequency
  • Front/rear mounting and bracket geometry
  • Feedback or end-stop requirement
  • Cable, connector and exit-direction requirements
  • Environmental exposure and required enclosure rating
  • Required test, material or compliance documentation

Evidence boundary

The current HR61 product media set contains product images but no independent drawing, datasheet, performance report, acoustic report, ingress-protection report, material certificate or compliance certificate. Exact electrical, mechanical, performance, environmental and compliance claims therefore require confirmation from approved project documentation before production.




OEM & Private Label Customization

ActuLift supports end-to-end customization, from structural design and stroke parameters to branding and casing finishes, helping you build a powerful brand identity.

Rapid Response & Prototyping

We understand the importance of speed in B2B procurement, utilizing optimized production workflows to ensure efficient responses from sample development to bulk delivery.

Quality Documentation & Traceability

Quality and traceability requirements vary by project. Ask ActuLift for the applicable inspection records, product specifications, drawings and available compliance documentation for the selected model and order.