Der IP800 ist ein Hochleistungs- Schwerlastlinearaktuator der bis zu 850 lbs dynamische Kraft liefert. Entwickelt für Gesundheitswesen und medizinische Geräte und robuste Außenautomation, verfügt er über eine IP67-Wasserdichtigkeit und anpassbare Hubgrößen.
Schnelle Spezifikationen im Vergleich
| Funktion | IP800 (Schwerlast) | IP600 (Standard) |
| Max. Dynamische Last | 850 lbs (3800N) | 1350 lbs (6000N) |
| Eingangsspannung | 12V / 24V DC | 12V / 24V DC |
| IP-Bewertung | IP66 / IP67 (Benutzerdefiniert) | IP54 / IP65 |
| Geschwindigkeit | 15 – 60 mm/s | 5 – 40 mm/s |
| Ideale Anwendung | Agrarwirtschaft & Medizin | Möbel & Industrie |
Kontaktieren Sie uns für ein Angebot und Informationen zu diesem Produkt:
The IP800 Heavy Duty Linear Actuator Custom is built for buyers who need controlled push-pull motion in a compact electric actuator package. It fits projects where load capacity, stroke length, sealing level, and voltage must be chosen around the equipment instead of forced into a fixed off-the-shelf part.
For procurement teams, the headline number is clear: this custom IP800 configuration is rated for 850 pounds (385 kilograms) dynamic load and 1700 pounds (770 kilograms) static load. That split matters. Dynamic load tells your engineer what the actuator can move while running. Static load tells the team what it can hold when the motion stops, subject to the final mounting design and application review.
The actuator can be specified with 12V DC or 24V DC input. That makes it easier to match the power system already used in mobile machinery, outdoor equipment, automation fixtures, or integrated motion assemblies. If your project already uses a 24V control platform, the 24V version can simplify system matching. If the equipment runs from a 12V battery or vehicle-side supply, the 12V option gives your team another route.
For related voltage categories, ActuLift also organizes products under 12V lineare Aktuatoren und 24V lineare Aktuatoren, which helps buyers compare platform-level options before locking the specification.
| Spezifikation | Details |
|---|---|
| Produktname | IP800 Heavy Duty Linear Actuator Custom |
| Zuschauer-Modus | B-end Großhandel/OEM |
| Eingangsspannung | 12V DC/24V DC optional |
| Maximale Tragfähigkeit | Dynamisch 850 Pfund (385 Kilogramm) / Statisch 1700 Pfund (770 Kilogramm) |
| Geschwindigkeit (leer/voll beladen) | 15-60 mm/s, einstellbares Übersetzungsverhältnis |
| Förderlänge | 30mm bis 1000mm (anpassbar) |
| Schutzlevel | Standard IP66, optional IP67 |
| Betriebstemperatur | -20 °C bis +60 °C (-4 °F bis 140 °F) |
| Geräuschpegel | <48 Dezibel (leiser als Bürogespräche) |
| Zertifizierung | CE-Zertifizierung, RoHS-Konformität, ISO 9001-Zertifizierung |
The IP800 is a good fit when your project needs more than a simple catalog actuator. The travel length can be customized from 30mm to 1000mm, so the same actuator family can serve short-stroke positioning, long-stroke opening, lifting, tilting, or access-panel motion. That flexibility is useful for OEM teams building several product sizes around one motion platform.
The speed range is 15-60 mm/s, with adjustable gear ratio selection. In practice, this gives your team room to choose between faster movement and stronger controlled motion. The final speed should be checked against load, stroke, duty cycle, controller rating, and end-user comfort. A fast actuator can look good on a spec sheet. A properly matched actuator is better.
For heavier applications, this product belongs in the same buying conversation as ActuLift’s schwere lineare Aktuatoren und wasserdichte lineare Aktuatoren. Those category links are useful when the buyer is comparing load rating, sealing level, and outdoor-use needs before asking for a quote.
The standard protection level is IP66, with IP67 available as an option. IEC explains that IP ratings grade enclosure resistance against dust and liquids under defined conditions, so the right choice depends on the actual environment. IP66 is commonly discussed for dusty or water-jet exposure. IP67 is the option to discuss when the design brief involves stronger water-ingress concerns. The final equipment layout still matters: cable exit, connector sealing, mounting angle, and enclosure drainage can change real-world results.
The working temperature range is -20 °C to +60 °C (-4 °F to 140 °F). That covers many industrial, mobile, and outdoor-adjacent applications, but buyers should still confirm cycle time, load, sealing, and lubricant behavior for the final use case. If the actuator will sit near heat sources, ice, washdown, dust, vibration, or side load, send those details before sample approval.
Noise is listed at <48 decibels, quieter than office conversations. That makes the IP800 easier to place in equipment where motion noise affects the user’s experience, such as adjustable furniture, indoor automation fixtures, service panels, or customer-facing machinery.
For an OEM build, the actuator is only one part of the motion system. You may also need mounting hardware, a control box, a handset, wiring, or feedback options. ActuLift’s related categories make that sourcing path easier: . Wir bieten kritische Montagesupport durch eine Vielzahl von help with pivot points and load transfer, while Steuerkästen und Steuerungen support system control. If position signal, handset operation, or coordinated motion is part of the design, confirm those requirements before sample production.
Before bulk order, the safest workflow is simple. Confirm the voltage. Confirm the real working load, not just the best-case load. Confirm stroke and retracted length. Check mounting points, side-load risk, cable direction, connector type, controller current, and duty cycle. Then approve a sample with the same mounting and control logic planned for production.
The brief lists CE certification, RoHS compliance, and ISO 9001 certification. For purchasing teams, those terms are useful but should still be tied to documents for the ordered configuration. CE marking is a manufacturer’s declaration that the product meets applicable CE requirements. RoHS relates to restricted hazardous substances in electrical and electronic equipment. ISO 9001 relates to the supplier’s quality management system.
In other words, these are not magic words that approve the final machine. They are part of the evidence package your team should request along with drawings, sample test notes, labeling details, and packaging requirements. For distributors or private-label customers, it is also worth confirming product nameplate content, carton labels, instruction sheets, and any market-specific documentation before mass production.
The listed maximum load capacity is dynamic 850 pounds (385 kilograms) and static 1700 pounds (770 kilograms). Keep those ratings separate during engineering review because moving load and holding load are not the same design condition.
Yes. The brief lists 12V DC and 24V DC as optional input voltage choices. Pick the version that matches your power supply, controller, cable length, current limits, and equipment architecture.
Travel length is customizable from 30mm to 1000mm. Before sampling, confirm the required stroke, installation distance, retracted length, extended length, and mounting style with the drawing.
The standard protection level is IP66, with IP67 optional. It is better to treat this as an ingress-protection specification under test conditions rather than a broad waterproof promise. Share the working environment so the sealing level, connector, and cable routing can be checked.
Confirm voltage, load, stroke, speed, mounting points, side load, controller match, cable/connector needs, protection level, operating temperature, labels, packaging, and compliance documents. A sample approval step is strongly recommended for OEM projects.
The IP800 Heavy Duty Linear Actuator Custom gives OEM buyers a strong, configurable actuator platform with 850 lb dynamic load, 1700 lb static load, 12V/24V options, 30mm to 1000mm travel, IP66 standard protection, and optional IP67 sealing. It works best when buyers share real load, stroke, mounting, controller, and environment details before sample approval.