ขาตั้งตัวกระตุ้นแบบแบน IP80 is a compact OEM linear-actuator platform for short-travel motion systems. The current product brief lists 24V DC with a 12V option, a 200N push/pull figure, 10–200mm stroke choices, multiple speed options, and IP42/IP65 enclosure variants.
Load, stroke, speed, noise, enclosure protection, controller compatibility, materials, and compliance documentation depend on the selected configuration. Confirm the current drawing, datasheet or engineering specification, test conditions, and required documents before sample approval or bulk ordering.
ติดต่อเราเพื่อต้องการราคาและข้อมูลเกี่ยวกับผลิตภัณฑ์นี้:
The IP80 is a compact linear-actuator platform for OEM equipment that needs short-travel motion in a limited installation space. The current product brief lists 24V DC with a 12V option and a 200N push/pull figure. Treat those as configuration-specific procurement inputs and confirm the selected motor, gearing, load direction, duty cycle, controller, and test conditions before sample approval.
Potential use cases include compact furniture mechanisms, vents or panels, fixtures, enclosure automation, and other light-motion OEM assemblies. Application suitability should not be inferred from the category name alone: confirm the actual load, stroke, mounting geometry, environment, duty cycle, noise target, and any industry-specific requirements for the finished equipment.
For buyers comparing ActuLift categories, this model belongs naturally with อุปกรณ์กระตุ้นเชิงเส้น 24V and compact OEM motion projects. If the same system needs higher enclosure protection, ask which IP-rated configuration is actually available for the selected build and request the current test documentation before comparing it with ActuLift’s กระตุ้นเชิงเส้นกันน้ำ. For heavier loads, the buyer should move the comparison toward กระตุ้นเชิงเส้นที่มีน้ำหนักมาก instead of forcing a compact model into the wrong job.
| สเปก | รายละเอียด |
|---|---|
| แรงดันไฟฟ้าเข้า | Current brief lists 24V DC with a 12V option; confirm the selected motor, controller, current requirement, and wiring. |
| มอเตอร์ซีรีย์ IP1200, IP800, IP3000 | Current brief lists 200N push/pull; confirm rated working load, load direction, duty cycle, mounting geometry, and test conditions. |
| ความเร็ว (โหลดไม่ทำงาน / โหลดเต็ม) | Current brief lists 4 / 8 / 15 / 30mm/s options; confirm the selected gearing, expected load, supply, and measured speed. |
| ขึ้นอยู่กับตัวกระตุ้นที่เชื่อมต่อ | Current brief lists 10–200mm; confirm available stroke, retracted/extended dimensions, and customization for the selected build. |
| ระดับการป้องกัน | Current brief lists IP42 and an IP65 option; confirm the exact enclosure build and current test documentation. |
| อุณหภูมิการทำงาน | Current brief lists -20°C to +60°C; confirm the selected motor, gearbox, lubrication, cable, controller, load, and actual environment. |
| ลักษณะเสียง | Current brief lists <45 dB; confirm load, speed, distance, measurement method, mounting structure, and test environment. |
| การรับรอง | Request current model/configuration-specific CE/RoHS or other applicable compliance documentation before approval. |
The current product brief lists 200N push/pull. Do not treat that figure as a universal working-load promise. Stroke length, load direction, bracket geometry, moving angle, friction, side load, duty cycle, controller output, gearing, and safety factor all affect the finished mechanism, so confirm the selected configuration against the actual load case.
For sample approval, ask engineering to confirm the actual moving load, the worst operating angle, and the force needed at startup. If the moving structure binds, even a correct load rating may not save the mechanism. A clean mechanical path matters.
The current brief lists 4, 8, 15, and 30mm/s speed options. Availability and achieved speed depend on the selected gearing, motor, supply, load, and controller. Confirm speed under the expected working load rather than selecting from the catalog number alone.
The current brief lists stroke choices within 10mm to 200mm. Confirm the exact available stroke together with retracted length, extended length, mounting-hole positions, cable exit, and surrounding clearance. Suitability for a door, panel, shutter, furniture module, tracking mechanism, or other application depends on the complete mechanical design.
When requesting a quote, include the target stroke, retracted length if known, mounting direction, cable direction, speed preference, voltage, and expected load. If your team has a CAD file or installation drawing, send it early. It saves time because the supplier can check whether the actuator, bracket, and moving structure have enough clearance.
For projects that need brackets or pivot hardware, pair the actuator discussion with เพื่อให้แน่ใจว่ามีการรวมทางกลที่ไม่ราบรื่น.. For systems that need hand operation or multi-actuator logic, review control boxes and controllers และ รีโมทคอนโทรลและแฮนด์เซ็ต before locking the sample.
The current product brief lists IP42 and an IP65 option. Do not infer indoor, outdoor, dust, spray, wash-down, or other environmental suitability from that option list alone. Confirm the exact enclosure, cable exits, connectors, mounting orientation, and current IP test documentation for the selected build.
Here is the plain version: do not treat IP65 as permission to ignore the rest of the design. Cable exits, connectors, mounting angle, cleaning method, duty cycle, and enclosure design still matter. IEC IP ratings describe defined enclosure protection tests. They do not replace final-equipment validation.
For B2B buyers, the safer purchasing question is not “is it waterproof?” It is “which protection grade matches our exact environment, and can we get the documents for this configuration?” That wording keeps the project honest.
The current product brief lists an acoustic figure below 45 dB. Treat that as a value requiring test-condition confirmation, not as a universal “silent” or “library-quiet” claim. Load, speed, mounting structure, resonances, distance, measurement method, and room conditions can materially change the observed result.
Noise still depends on the complete mechanism. A quiet actuator can sound rough if the frame resonates, the bracket is loose, or the load is not guided. During sample testing, run the actuator inside the real structure when possible. Bench testing is useful, but it does not tell the whole story.
If the buyer is building a people-facing product line, this model should be tested inside the finished structure, with the real bracket and enclosure, before sample approval.
The IP80 is positioned for OEM configuration work. Buyers can define voltage, stroke, required speed, protection target, mounting style, wiring, controller interface, and documentation needs, but final availability and performance should be captured in the selected-build specification and validated through sampling.
Before mass production, confirm these items:
Do not treat a generic CE/RoHS statement as evidence for every IP80 configuration. Request the current model- and configuration-specific declarations, reports, or material-compliance records needed for import review, tender files, or distributor onboarding. The buyer’s finished equipment may have separate compliance obligations.
For a faster quote, send a short technical brief instead of only asking for price. A useful version looks like this:
This kind of brief gives the supplier enough information to respond with something useful. It also reduces the chance of approving a sample that looks right on the bench but fails once mounted in the finished product.
The IP80 is a compact OEM actuator platform whose final suitability depends on the selected voltage, rated working load, stroke and installation length, gearing and load-dependent speed, enclosure protection, noise target, mounting geometry, duty cycle, controller interface, environment, and required documentation. Confirm those items on the selected build before production approval.